{"id":7420,"date":"2025-06-30T20:20:08","date_gmt":"2025-06-30T18:20:08","guid":{"rendered":"https:\/\/bieler-lang.de\/?post_type=product&#038;p=7420"},"modified":"2025-09-22T09:54:46","modified_gmt":"2025-09-22T07:54:46","slug":"exdetector-sc-220","status":"publish","type":"product","link":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/","title":{"rendered":"ExDetector SC 220"},"content":{"rendered":"<p>The <strong>ExDetector SC 220<\/strong> can be used to detect flammable gases and vapors in the measuring range from 0 to 50 % LEL. A semiconductor gas sensor is used for measurement, which is very robust. It is often a sensible alternative to other sensors that cannot be used due to the presence of catalyst poisons in the atmosphere.<\/p>\n<p>&nbsp;<\/p>\n<p>The <strong>ExDetector SC 220<\/strong> can be used in Ex zone 2.<\/p>\n<p>Because safety counts.<\/p>\n<p>The <strong>ExDetector SC 220<\/strong> is stand-alone capable, i.e. it can independently initiate protective measures without the additional use of an evaluation unit. Integrated low-voltage switching outputs for pre-alarm, main alarm and sensor fault are available. It can also be conventionally connected to an evaluation unit.<\/p>\n<p>\u25cf <strong>Standalone mode<\/strong><br \/>\nThe integrated alarm evaluation is switched on. Two alarm levels with switch-off hysteresis can be stored in the programming. Alarm level 1 (pre-alarm) switches a non-latching NC contact and alarm level 2 (main alarm) switches a latching NC contact. After falling below this alarm threshold, the alarm is retained and must be acknowledged via the reset input. A fault signaling contact signals malfunction and overrange. In addition, the measured value is output as a 4 &#8211; 20 mA current signal for further processing.<\/p>\n<p>\u25cf <strong>Transmitter CL<\/strong><br \/>\nIf the alarm evaluation functionality is not required, the sensor can be operated with the integrated CL option. In this case, the sensor supplies the measured gas concentration in the form of a 4 &#8211; 20 mA current signal for<br \/>\nfurther processing in an alarm control center; the alarm switching contacts are not activated. Suitable signal conditioning instruments include GMC 8043, GMC 8032, GMC 8022, GMC 8022E, GMC 8364.<\/p>\n<h6><\/h6>\n<h4>Features of the ExDetector SC 220:<\/h4>\n<ul>\n<li>Explosive gases and vapors &#8211; 3 sensor types available:<br \/>\nSensor type M: Methane, &#8230;<br \/>\nSensor type P: Propane, heptane, hydrogen, &#8230;<br \/>\nSensor type S1: Frigene such as R134a, &#8230;<\/li>\n<li>Measuring range 0 &#8211; 50 % LEL (lower explosion limit)<\/li>\n<li>Measuring principle <strong><strong><strong>Semiconductor gas sensor<\/strong><\/strong><\/strong><\/li>\n<li>Stand alone mode possible<\/li>\n<li>One-person calibration with <strong>Calibrationbox-i<\/strong><\/li>\n<li>Linear measuring signal 4 &#8211; 20 mA<\/li>\n<li>Integrated switching outputs for:<br \/>\n&#8211; Alarm 1 (pre-alarm)<br \/>\n&#8211; Alarm 2 (main alarm)<br \/>\n&#8211; Sensor fault<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Accessories<\/h4>\n<ul>\n<li>Test gas set<\/li>\n<li>Calibration gases<\/li>\n<li>Calibrationbox-i control unit<\/li>\n<li>Evaluation devices<\/li>\n<li>Mounting bracket<\/li>\n<li>Remote gassing adapter <strong>FBA2018<\/strong>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"text-align: left;\"><\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"text-align: left;\"><\/div>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>ExDetector SC 220<\/strong> can be used to detect flammable gases and vapors in the measuring range from 0 to 50 % LEL. A semiconductor gas sensor is used for measurement, which is very robust. This is often a sensible alternative to other sensors that cannot be used due to the presence of catalyst poisons in the atmosphere.<\/p>\n<p>The <strong>ExDetector SC 220<\/strong> is stand-alone capable, i.e. it can independently initiate protective measures without the additional use of an evaluation unit. Integrated low-voltage switching outputs for pre-alarm, main alarm and sensor fault are available. It can also be conventionally connected to an evaluation unit.<\/p>\n<p>The <strong>ExDetector SC 220<\/strong> can be used in Ex zone 2.<\/p>\n<p>&nbsp;<\/p>\n<h6>Special features:<\/h6>\n<ul>\n<li>Explosive gases and vapors<br \/>\nSensor type M: Methane, &#8230;<br \/>\nSensor type P: Propane, heptane, hydrogen, &#8230;<br \/>\nSensor type S1: Frigene such as R134a, &#8230;<\/li>\n<li>Measuring range 0 &#8211; 50 % LEL (lower explosion limit)<\/li>\n<li>Measuring principle <strong><strong><strong>Semiconductor gas sensor<\/strong><\/strong><\/strong><\/li>\n<li>Stand alone mode possible<\/li>\n<li>One-person calibration with <strong>Calibrationbox-i<\/strong><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h6>Our quality standards:<\/h6>\n<ul>\n<li>Solid design in a robust housing<\/li>\n<li>Durable with low maintenance costs<\/li>\n<li>Developed and manufactured in Germany<\/li>\n<\/ul>\n","protected":false},"featured_media":1527,"template":"","meta":{"inline_featured_image":false},"product_brand":[],"product_cat":[102,101,104,115,111,109,219,221,118,110,120],"product_tag":[231,284,232,241,261],"class_list":{"0":"post-7420","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-atex-en","7":"product_cat-ex-zone-2-en","8":"product_cat-explosive-flammable-gases-en","9":"product_cat-gas-sensors-gas-detectors","10":"product_cat-hazardous-goods-storage","11":"product_cat-laboratories-en","12":"product_cat-lpg-lng-cng-en","13":"product_cat-refrigerant-monitoring-en","14":"product_cat-semiconductor-sensors-en","15":"product_cat-sewage-treatment-plant-en","16":"product_cat-tunnels-en","17":"product_tag-c3h8-propan-en","18":"product_tag-c7h16-heptane","19":"product_tag-ch4-methane","20":"product_tag-h-hydrogen","21":"product_tag-r-134a-en","23":"first","24":"instock","25":"shipping-taxable","26":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ExDetector SC 220 - Bieler+Lang<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ExDetector SC 220\" \/>\n<meta property=\"og:description\" content=\"The ExDetector SC 220 can be used to detect flammable gases and vapors in the measuring range from 0 to 50 % LEL. A semiconductor gas sensor is used for measurement, which is very robust. This is often a sensible alternative to other sensors that cannot be used due to the presence of catalyst poisons in the atmosphere.  The ExDetector SC 220 is stand-alone capable, i.e. it can independently initiate protective measures without the additional use of an evaluation unit. Integrated low-voltage switching outputs for pre-alarm, main alarm and sensor fault are available. It can also be conventionally connected to an evaluation unit.  The ExDetector SC 220 can be used in Ex zone 2.  &nbsp; Special features:   Explosive gases and vapors Sensor type M: Methane, ... Sensor type P: Propane, heptane, hydrogen, ... Sensor type S1: Frigene such as R134a, ...  Measuring range 0 - 50 % LEL (lower explosion limit)  Measuring principle Semiconductor gas sensor  Stand alone mode possible  One-person calibration with Calibrationbox-i  &nbsp; Our quality standards:   Solid design in a robust housing  Durable with low maintenance costs  Developed and manufactured in Germany\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/\" \/>\n<meta property=\"og:site_name\" content=\"Bieler+Lang\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61560570132188\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-22T07:54:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bieler-lang.de\/blcontent\/uploads\/2020\/09\/BL_GasDetector-SC220_01ex.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/\",\"url\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/\",\"name\":\"ExDetector SC 220 - Bieler+Lang\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bieler-lang.de\\\/blcontent\\\/uploads\\\/2020\\\/09\\\/BL_GasDetector-SC220_01ex.jpg\",\"datePublished\":\"2025-06-30T18:20:08+00:00\",\"dateModified\":\"2025-09-22T07:54:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bieler-lang.de\\\/blcontent\\\/uploads\\\/2020\\\/09\\\/BL_GasDetector-SC220_01ex.jpg\",\"contentUrl\":\"https:\\\/\\\/bieler-lang.de\\\/blcontent\\\/uploads\\\/2020\\\/09\\\/BL_GasDetector-SC220_01ex.jpg\",\"width\":1200,\"height\":1080,\"caption\":\"Bieler+Lang_ExDetector SC 220_Ex-Zone 2\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/product\\\/exdetector-sc-220\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bieler-lang.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ExDetector SC 220\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bieler-lang.de\\\/#website\",\"url\":\"https:\\\/\\\/bieler-lang.de\\\/\",\"name\":\"Bieler+Lang\",\"description\":\"Eine weitere WordPress-Website\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bieler-lang.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"ExDetector SC 220 - Bieler+Lang","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/","og_locale":"en_US","og_type":"article","og_title":"ExDetector SC 220","og_description":"The ExDetector SC 220 can be used to detect flammable gases and vapors in the measuring range from 0 to 50 % LEL. A semiconductor gas sensor is used for measurement, which is very robust. This is often a sensible alternative to other sensors that cannot be used due to the presence of catalyst poisons in the atmosphere.  The ExDetector SC 220 is stand-alone capable, i.e. it can independently initiate protective measures without the additional use of an evaluation unit. Integrated low-voltage switching outputs for pre-alarm, main alarm and sensor fault are available. It can also be conventionally connected to an evaluation unit.  The ExDetector SC 220 can be used in Ex zone 2.  &nbsp; Special features:   Explosive gases and vapors Sensor type M: Methane, ... Sensor type P: Propane, heptane, hydrogen, ... Sensor type S1: Frigene such as R134a, ...  Measuring range 0 - 50 % LEL (lower explosion limit)  Measuring principle Semiconductor gas sensor  Stand alone mode possible  One-person calibration with Calibrationbox-i  &nbsp; Our quality standards:   Solid design in a robust housing  Durable with low maintenance costs  Developed and manufactured in Germany","og_url":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/","og_site_name":"Bieler+Lang","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61560570132188","article_modified_time":"2025-09-22T07:54:46+00:00","og_image":[{"width":1200,"height":1080,"url":"https:\/\/bieler-lang.de\/blcontent\/uploads\/2020\/09\/BL_GasDetector-SC220_01ex.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/","url":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/","name":"ExDetector SC 220 - Bieler+Lang","isPartOf":{"@id":"https:\/\/bieler-lang.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/#primaryimage"},"image":{"@id":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/#primaryimage"},"thumbnailUrl":"https:\/\/bieler-lang.de\/blcontent\/uploads\/2020\/09\/BL_GasDetector-SC220_01ex.jpg","datePublished":"2025-06-30T18:20:08+00:00","dateModified":"2025-09-22T07:54:46+00:00","breadcrumb":{"@id":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/#primaryimage","url":"https:\/\/bieler-lang.de\/blcontent\/uploads\/2020\/09\/BL_GasDetector-SC220_01ex.jpg","contentUrl":"https:\/\/bieler-lang.de\/blcontent\/uploads\/2020\/09\/BL_GasDetector-SC220_01ex.jpg","width":1200,"height":1080,"caption":"Bieler+Lang_ExDetector SC 220_Ex-Zone 2"},{"@type":"BreadcrumbList","@id":"https:\/\/bieler-lang.de\/en\/product\/exdetector-sc-220\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bieler-lang.de\/en\/"},{"@type":"ListItem","position":2,"name":"ExDetector SC 220"}]},{"@type":"WebSite","@id":"https:\/\/bieler-lang.de\/#website","url":"https:\/\/bieler-lang.de\/","name":"Bieler+Lang","description":"Eine weitere WordPress-Website","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bieler-lang.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/product\/7420","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/media\/1527"}],"wp:attachment":[{"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/media?parent=7420"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/product_brand?post=7420"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/product_cat?post=7420"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/bieler-lang.de\/en\/wp-json\/wp\/v2\/product_tag?post=7420"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}