Biogas
Devices for room monitoring, e.g. in the CHP unit
The explosion protection rules (EX-RL, DGUV Rule 113-001) of the BG RCI contain important safety rules. There is also Technical Information 4 “Safety rules for biogas plants” (TI 4) from the German Federal Association of Agricultural Employers’ Liability Insurance Associations, which contains instructions for the construction and operation of agricultural biogas plants.
If gas warning devices are used in biogas plants for room monitoring, they should at least correspond to Ex zone 2 in accordance with TI 4.
GMC Biogas 08
Biogas analyzer
In order to optimally control the production process in a biogas plant, continuous monitoring of the biogas produced is required.
With the GMC Biogas 08 biogas analysis system , the levels of residual oxygen, methane, carbon dioxide and hydrogen sulphide are determined in individually defined measuring cycles.
The reasons for using the GMC Biogas 08 biogas analyzer from Bieler + Lang are as follows:
- Double infrared measuring bench for CH4 and CO2
- H2S sensor in separate sample gas path with independently adjustable measuring interval
- Overload protection for the H2S sensor
- Very good price-performance ratio
- Simple, menu-guided operation
- Modular design, good expandability
- Low maintenance effort
- Integrated data logger for 1440 data records including data output in Excel (via RS 232 interface)
- Active control of the pump function before each measurement
- Automatic zero-point calibration of the sensors before each measurement
Possible additional options:
- Connection of up to two gas sensors for room monitoring
- Sample gas cooler with automatic condensate drainage:
- Gas dehumidification by means of Peltier cooling, initial temperature of the sample gas: +5 degrees Celsius
- Relay module for switching external alarms
- Fieldbus module
- Measuring point switchover to up to four intake points


Brochure
Brochure Biogas analyzer GMC Biogas 08