ExDetector HC 150 / HC 150 K

The ExDetector HC 150 sensor is used to measure the current concentration of explosive gases and vapors.

The ExDetector HC 150 can be used to detect explosive gases and vapors in the measuring range from 0 to 100 % LEL. The measuring principle is based on catalytic combustion (heat tinting). This measuring principle can be used to monitor a large number of gases, e.g. hydrogen and hydrocarbons.

It also meets all the criteria for use in Ex zone 2 and in areas of functional safety in accordance with SIL-1.

Variant for duct installation and high ambient temperatures:

ExDetector HC 150 K

 

The ExDetector HC 150-K sensor was specially developed for duct installation and has a transmitter that is separate from the sensor head.

This special combination is used to measure the current concentration of explosive gases and vapors in a pipe network.

 

Certified:
  • ATEX
  • Use in hazardous areas of Ex zone 2
  • Tested measuring function for methane, ethane, propane, butane,
    n-pentane and n-hexane in air
  • SIL 1
Special features:
  • Measuring range 0 – 100 % LEL (lower explosion limit)
  • Measuring principle catalytic combustion (heat tinting)
  • Linear measuring signal 4 – 20 mA
  • Measuring function (conformity statement): BAM 16 ATEX 0801 X
  • One-man calibration – direct adjustment at the sensor
  • HC 150 K: Remote sensor head can withstand temperatures up to 80 degrees Celsius

 

Our quality standards:
  • Solid design in a robust housing
  • Durable with low maintenance costs
  • Developed and manufactured in Germany
Send request
Name

By clicking Submit, I confirm that I have read and agree to the privacy policy.

Measuring heads

Measuring head gas Measuring range
Pellistor sensors (heat exchanger)
Flammable gases – of which tested 0 – 100% LEL
Tested gases (in air)
Methane 0 – 100% LEL
Ethane 0 – 100% LEL
Propane 0 – 100% LEL
Butane 0 – 100% LEL
n-pentane 0 – 100% LEL
n-hexane 0 – 100% LEL

Measurable gases

The following gases can be monitored with the ExDetector HC 150.

  • Explosive gases
  • explosive vapors
  • Methane
  • Ethan
  • Propane
  • Butane
  • n-pentane
  • n-hexane

This sensor is not suitable for monitoring solvent vapors.

Description

The ExDetector HC 150 sensor is used to measure the current concentration of explosive gases and vapors.

The ExDetector HC 150 can be used to detect explosive gases and vapors in the measuring range from 0 to 100 % LEL. The measuring principle is based on catalytic combustion (heat tinting). This measuring principle can be used to monitor a large number of gases, e.g. hydrogen and hydrocarbons.

It meets all the criteria for use in Ex zone 2 and in areas of functional safety in accordance with SIL-1.

Variant for duct installation and high ambient temperatures:

ExDetector HC 150 K

 

The ExDetector HC 150-K sensor was specially developed for duct installation and has a transmitter that is separate from the measuring head. It can be mounted on duct shafts using a mounting flange in order to detect hazardous gas concentrations inside.

This special combination is also used to measure the current concentration of explosive gases and vapors in a pipe network.

A particularly unique feature of this combination: the remote sensor in the measuring head of the HC 150 K sensor module, our “duct sensor”, can be used in an environment up to max. 80 degrees Celsius inside the duct, while the more temperature-sensitive components (up to 55 degrees Celsius) perform their duties outside these critical temperatures. A unique solution for problematic temperatures and atmospheres.

Functionality of the ExDetector HC 150 within a gas warning system:

 

The ExDetector HC150 series sensors in combination with evaluation systems have the following functions:

  • Measurement and display of the current concentration of explosive gases and vapors
  • Monitoring or warning of these gases
  • Triggering of protective measures:
    – Technical: The increase in concentration is counteracted (fans; shutdowns….)
    – Organizational: Visual and acoustic messages
  • A gas warning system consists of the following components:
    – Sensor
    – Evaluation system
    – Controllable devices such as fans, warning signs and solenoid valves

 

Accessories for the ExDetector HC 150:

  • Test gas set
  • Calibration gases
  • Evaluation devices
  • Mounting bracket
  • Remote gassing adapter FBA 2018

Technical Data

Sensor type

Pellistor (heat tinting – catalytic combustion)

Measuring range

Measuring range 0 – 100 % LEL (lower explosion limit)

Prototype

II 3G
Ex nA de IIC T4 Gc
PTB 10 ATEX 1023

Measuring function

BAM 16 ATEX 0801 X for methane, ethane, propane, butane,
n-pentane and n-hexane in air

Detectable gases

Explosive gases and vapors
including methane, ethane, propane, butane,
n-pentane and n-hexane

Measuring signal

linear 4 -20 mA

One-man calibration

Direct adjustment at the sensor

Other

3-wire technology

Further information

See data sheet

Downloads

Accessories

Verwandte Produkte